Three-phase AC panel without RCD - 20A
Three-phase AC panel without RCD - 20A
*VAT excluded.
**SHIPPING EXCLUDED
20A 400Vac Three-Phase Photovoltaic AC Panel for Single 8/9 kW Inverter Without Interface Protection
The 20A 400Vac three-phase photovoltaic AC panel for a single 8/9 kW inverter without interface protection is an electrical panel designed for the management, protection, and distribution of the alternating current (AC) side in small and medium-sized photovoltaic systems with a single three-phase inverter.
The electrical panel is configured to manage an 8/9 kW three-phase photovoltaic inverter and includes protection, isolation, and surge protection devices to ensure the safe operation of the system and the correct distribution of the AC electrical line.
This AC panel for photovoltaic systems is made of a wall-mounted ABS enclosure with an IP65 protection rating and is suitable for installation in outdoor environments, thanks to the presence of selected components, internal wiring, cable glands, and identification labels.
Function of the AC Panel in Photovoltaic Systems
The photovoltaic AC electrical panel represents the collection and protection point of the alternating current line between the inverter and the electrical system. Its main function is to ensure electrical safety, component protection, and system continuity.
The panel includes devices dedicated to protecting the electrical line, such as:
- miniature circuit breakers
- residual current circuit breaker
- surge protection device (SPD)
- fuse holder with protection fuses
The configuration protects the AC side of the system from overloads, residual current faults, and overvoltages caused by atmospheric conditions or switching operations, contributing to the overall safety of the photovoltaic system.
The compact design of the enclosure, along with the input/output terminals, ground bar, and cable glands, also facilitates connection and installation operations.
The panel is supplied with paper technical documentation, an electrical diagram, and visual instructions to ensure the correct connection of the components during installation.
Main Features of the 20A Photovoltaic AC Panel
- AC side management of a single 8/9 kW three-phase photovoltaic inverter
- 20A rated current at 400Vac
- Configuration without interface protection
- 12+12 module wall-mounted ABS enclosure
- IP65 protection rating for installation in outdoor environments
- Thermal-magnetic line protection with 2 4P 20A C-curve miniature circuit breakers
- 4P 300mA Type A residual current circuit breaker
- 3P+N Type 2 40kA 420Vac surge protection device (SPD)
- Fuse holder with 3 32A gG 10.3x38 fuses
- Input/output terminals, ground bar, internal wiring, cable glands, and labeling
Applications of the Three-Phase Photovoltaic AC Panel
- Photovoltaic systems with a single 8/9 kW three-phase inverter
- Small-scale residential and commercial photovoltaic installations
- Photovoltaic systems with low-voltage AC side management
- Photovoltaic systems with a dedicated protection and distribution panel
- Outdoor installations thanks to the IP65 enclosure
- Photovoltaic systems requiring protection against overvoltages and residual current faults
- Solar photovoltaic power generation systems with three-phase inverters
Components Included in the AC Electrical Panel
- 1 12+12 module IP65 wall-mounted ABS enclosure
- 2 4-pole 20A C-curve miniature circuit breakers
- 1 4-pole 300mA Type A residual current circuit breaker
- 1 3P+N Type 2 40kA 420Vac surge protection device (SPD)
- 1 fuse holder with 3 32A gG 10.3x38 fuses
- Input/output terminals
- Ground bar
- Internal wiring
- Cable glands
- Labeling
- Wall plugs and screws for wall mounting
- Paper documentation with electrical diagram and visual connection instructions
Technical Specifications of the Photovoltaic AC Panel
| Panel type | Three-phase photovoltaic AC electrical panel for a single inverter without interface protection |
|---|---|
| Inverter configuration | 1 8/9 kW three-phase inverter |
| Rated current | 20A |
| Rated voltage | 400Vac |
| Residual current protection | 4P 300mA Type A residual current circuit breaker |
| Overvoltage protection | 3P+N Type 2 40kA 420Vac SPD |
| Enclosure protection | IP65 |
| Panel structure | 12+12 module wall-mounted ABS enclosure |
Installation of the AC Electrical Panel for Photovoltaic Systems
The AC electrical panel is designed for wall mounting and is made of a robust ABS enclosure with an IP65 protection rating, suitable for outdoor environments.
The supply includes useful accessories for practical and tidy installation, such as wall plugs, screws, and an appropriate number of cable glands for freely connecting the input and output cables.
The panel is completed with internal wiring, safety and component identification labels, as well as supporting technical documentation to facilitate connection and installation operations.
Frequently Asked Questions About the Photovoltaic AC Panel
For which systems is this AC panel designed?
The AC panel is designed for photovoltaic systems with a single 8/9 kW three-phase inverter and a rated current of 20A at 400Vac.
Does the panel include interface protection?
No, this configuration does not include interface protection and is equipped with miniature circuit breakers, a residual current circuit breaker, and a surge protection device for AC side management.
What is included in the panel supply?
The panel is supplied complete with an IP65 enclosure, protection devices, input/output terminals, a ground bar, internal wiring, cable glands, labeling, wall plugs, screws, an electrical diagram, and visual instructions for correct connection.
Related search terms
20A three-phase photovoltaic AC panel, 8/9 kW three-phase inverter 400Vac AC panel, photovoltaic electrical panel without interface protection, AC panel for single three-phase inverter, IP65 photovoltaic panel with Type 2 SPD, three-phase AC panel with Type A residual current circuit breaker, 20A 400Vac photovoltaic electrical panel, wall-mounted three-phase photovoltaic AC enclosure
Couldn't load pickup availability
Important notes: Shipping and order handling costs are not included and will be communicated later during the quoting phase. These costs are due regardless of the chosen delivery method, including pickup at the premises.
Product prices may vary depending on availability and supplier terms at the time of the quote request. Images are for illustrative purposes only and may not accurately reflect the actual product; descriptions may contain errors. We recommend always checking the manufacturer's technical data sheet.
Share